01
Orbit Motors/Gerotor Motors/Cycloidal Motors
(ml/r) | Displacement | 50 | 63 | 80 | 100 | 125 | 160 | 200 | 250 | 315 | 400 |
(LPM) Flow | Cont. | 38 | 45 | 58 | 58 | 58 | 58 | 58 | 58 | 58 | 58 |
(LPM) Flow | Int.. | 45 | 53 | 69 | 69 | 69 | 69 | 69 | 69 | 69 | 69 |
(RPM) Speed | Cont. | 698 | 663 | 685 | 560 | 456 | 356 | 285 | 236 | 179 | 145 |
(RPM) Speed | Int.. | 858 | 775 | 820 | 671 | 548 | 426 | 341 | 282 | 210 | 173 |
(MPa) Pressure | Cont. | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | 12.5 | 11 | 10 | 9 | 9 |
(MPa) Pressure | Int.. | 14 | 14 | 14 | 14 | 14 | 12.5 | 12.5 | 12.5 | 12.5 | 11 |
(N*m) Torque | Cont. | 74 | 87 | 124 | 155 | 194 | 227 | 282 | 302 | 365 | 456 |
(N*m) Torque | Int.. | 86 | 98 | 141 | 176 | 221 | 260 | 318 | 383 | 406 | 521 |
04
7 Jan 2019
1. Intermittent means the entrance of the maximum pressure;continuous working pressure means the differential pressure.
2. Motor should not work under the highest pressure and the maximum speed.
3. The running time should not exceed 10% under intermittent working conditions.
4. The Maximum working temperature is 80°.
5. The Maximum allowable back pressure is 10 MPa,but the recommended back pressure should not exceed 5PM.a drain pipes is needed when exceeding.
6. One hour running time under 40% of maximum working pressure is recommended before full capacity working.
7. Recommending N68 anti-wear hydraulic oil,viscosity 37-73cSt,cleanliness ISO18/13.