01
Bosch Rexroth A2FE Axial Piston Motor – Series 6X
04
7 Jan 2019
General
The motor case must be completely filled with hydraulic fluid during commissioning and during operation (filling the case chamber).
The motor must be started at low speed and no load until the system has been bled completely.
If stopped for an extended period, fluid may drain out of the case through the service lines. When restarting, make sure that the case contains sufficient fluid.
The leakage fluid inside the case chamber must be drained off to the tank through the highest case drain port.
Installation below the tank
Motors below min. oil level in the tank (standard)
– Fill axial piston motor before startup via the highest case drain port
– Run the motor at low speed until the system is filled completely (bleed through service line port A, B if tubing is long)
– Minimum immersion depth of leakage line in tank: 200 mm (relative to the min. oil level in the tank)